4.3 Cleaning
Clean the device only when it is switched off and cold.
Clean the housing of the device only with a slightly damp, soft
cloth. Never use harsh and/or abrasive cleaning agents.
Make sure that no moisture enters the device during cleaning
to avoid irreparable damage to the device.
You can also remove dust deposits using an air blow gun (at low
pressure).
4.4 Transport
Using the transport handle 1 the compressor can be trans-
ported on its wheels 7
.
Never transport the compressor when the pressure vessel 5 is
pressurised.
4.6 Troubleshooting
Malfunction
Engine does not start.
Unusual noises
Strong vibrations
Compressor switches on frequently.
Compressor runs without interruption /
compressor does not reach cut-off pres-
sure.
14
GB/IE/NI/CY/MT
4.5 Storage
To protect against contamination, the compressor should be
covered after each use. The packaging can be used to store
the compressor.
Do not cover the compressor until it has cooled down com-
pletely.
Keep the compressor and its manual together. Store the ma-
chine and its accessories in a dark, dry, dust-free and frost-
free place.
Never transport the compressor when the pressure vessel 5 is
pressurised.
Store the oil bottle
ly closed in a dry, well-ventilated place. Keep away from fire
and heat. Store away from food and strong oxides. Store under
lock and key.
Possible cause(s)
No or too low voltage.
Outdoor temperature too low.
Device is not switched on.
There is not enough oil in the pump sys-
tem.
Extension cable is too long or too thin.
The motor has overheated. Overload
switch
has been tripped.
24
Pneumatic connectors are loose.
Pneumatic connectors are loose.
Compressor is overloaded.
Too much condensation in the pressure
vessel 5   .
Air consumption for connected pneumatic
tools and devices is too high.
Quick couplings
&
leaking.
12
14
Pneumatic connectors leaking.
in a cool place. Store the container tight-
22
Remedy
Make sure that the mains plug is inserted
in the socket. Check the fuse and replace
it if necessary. Check the mains voltage.
Ensure +5 °C ambient temperature.
Press the on/off switch
to position "I",
2
to switch on the compressor.
Check the oil level and top up if neces-
sary.
Replace the extension cable (min. 1.5
mm², max. 5 m long).
Allow the compressor to cool down and
press the overload switch
24
compressor.
Check all connecting parts and tighten
them carefully if necessary.
Servicing and maintaining the compressor.
Observe the manufacturer's instructions
for your tool or equipment, especially with
regard to the amount of compressed air
required.
Empty the pressure vessel 5 regularly.
Comply with the manufacturer's instruc-
tions for your pneumatic tool, especially
with regard to the amount of compressed
air required.
Check quick couplings
&
12
necessary.
Check pneumatic hose and tools, replace
if necessary.
. Restart the
  , replace if
14