Divator Pro regulator and Divator Pro Nitrox regulator
During use
Checks during diving
1.
Check the pressure gauge repeatedly to monitor gas consumption.
Terminate the dive with sufficient gas pressure to be able to return safely
to the surface or to the entry point of the dive.
2.
Check for leaks or abnormal behavior of the diving apparatus (small
bubbles will occasionally leave the anti-freeze device and are expected
when ascending, this is normal).
3.
Check that optional equipment fitted to the Divator Pro regulator can be
reached and managed.
4.
If using a DP1 surface supply: check that gas is not consumed from the
SCUBA cylinder. See the DP1 surface supply user manual for additional
details.
Warning
If using the DP1 system and the DP1 system is not supplying
enough gas to the diver, the indication that bail out gas is
consumed is that the diver's pressure gauge will decrease.
Extreme conditions
Diving in extreme conditions, such as diving in cold environments, requires
special training, planning and preparation.
Refer to the separate instruction with document number 34228, available on
the download section of interspiro.com, for more information.