Herunterladen Diese Seite drucken

INTERSPIRO Divator Pro Bedienungsanleitung Seite 14

Regulator
Vorschau ausblenden Andere Handbücher für Divator Pro:

Werbung

Divator Pro regulator and Divator Pro Nitrox regulator
Before use
Visual inspection
1.
Make sure that the regulator is clean and free from sand and/or debris
from previous use.
2.
Check all visible O-rings.
Damaged or missing O-rings must be replaced by an Interspiro certified
service technician.
3.
Inspect the regulator to detect if it has any signs of damage. A damaged or
defective regulator must be replaced or repaired by an Interspiro certified
service technician.
4.
Check all hoses by pulling and bending them while inspecting for damage,
cracks and discolouration. If a hose is found to be defective or damaged, it
must be replaced by an Interspiro level 3 certified service technician.
5.
Ensure that the gas pressure is sufficient (and, if applicable, the Nitrox
mixture is correct) for the planned dive. This applies to all cylinders to be
used for the dive.
Warning
The gas loss caused by a leak in the dry-suit hose or the BC
inflation hose is just as great as that caused by a leak in the
breathing hose.
14