Divator Pro regulator and Divator Pro Nitrox regulator
Reserve valve
The diver gets an active breathing resistance warning when approximately 20%
of the SCUBA cylinder gas supply remains.
The warning will activate no lower than 50 bar (725 PSI). On greater depth
and/or with higher ventilation, the warning will activate earlier.
The breathing resistance warning is created by reducing the gas supply at the
end of each inhalation. The inhalation phase will be shorter and shorter until
the valve becomes completely closed. When the reserve lever is turned to
reserve position, the breathing resistance warning is shut off.
• Dive position
• Reserve position
It is not possible to inadvertently or prematurely activate the reserve valve
lever; it will automatically reset itself to dive position until the gas supply
pressure has dropped below approximately 80 bar (1160 psi).