Herunterladen Inhalt Inhalt Diese Seite drucken

Rommelsbacher CT 2215/IN Bedienungsanleitung Seite 31

Induktions kochtafel
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

E5
Overheating protection ("power level" mode): The temperature on the cooktop exceeds
the maximum allowable value of 200 °C during "power level" operating mode (e. g. due
to hot oil or fat, or an empty pot or any other metal object while appliance is switched on).
Self-help: Eliminate the cause of overheating. Once the cooktop has cooled, the appliance
can be put into operation again. Afterwards use the "temperature level" mode for
constantly higher temperatures over 200 °C.
E6
Temperature sensor: The temperature sensor underneath the glass ceramic plate is
defective.
Self-help: Not possible – the appliance must certainly be forwarded to the customer
service.
E7
Overheating protection ("temperature level" mode): The temperature on the cooktop
exceeds the maximum allowable value of 240 °C during "temperature level" mode
(e. g. due to an empty pot or any other metal object while appliance is switched on).
Self-help: Eliminate the cause of overheating. Once the cooktop has cooled, the appliance
can be put into operation again.
E8
Temperature sensor: The temperature sensor underneath the glass ceramic plate
provides an undefined signal.
Self-help: Make sure no metal objects or other foreign objects were placed on the cooktop.
E11
Inside temperature: The interior of the appliance has become too warm (e. g. by
hindered air supply, blocked or defective fan or excessive ambient temperature).
Self-help: Clean the air vents or remove any foreign objects possibly located there,
improve the air supply.
E12
Safety shutdown: The Safety shutdown becomes active if one or more sensors operated
permanently for 20 s or more.
Self-help: Remove the cause. The instrument will switch automatically to „Standby" mode
and can be started up again.
NOTE: If the error cause is eliminated while error codes E1 or E2 are being displayed, the appli-
ance will automatically resume operation subject to the previous setting.
With regard to error codes E3 – E11 you will have to reset the control manually by pulling the
mains plug
If error code E 12 appears just restart the unit by using the main switch „ON/OFF".