GENERAL SAFETY WARNINGS

This installation manual is intended for professionally competent personnel only. Installation, electrical connections and
adjustments must be performed in accordance with Good Working Methods and in compliance with the present standards.
Read the instructions carefully before installing the product. Bad installation could be dangerous. Before installing the product,
make sure it is in perfect condition. Use original spare parts only for repairs or replacements of products.
1.

TECHNICAL DATA

Refer to the technical specifications and EC Declaration of Conformity in the BIS, TEN, VOLO and REX automation's manuals.
2.

ELECTRICAL CONNECTIONS

Warning: make a jumper on all N.C. contacts if not in use. The terminals with the same number are equal.
2.1 Commands
Command
1
2
N.O.
AUTOMATIC CLOSING
1
3A
N.O.
SIDE A OPENING
1
3B
SIDE B OPENING
1
4
N.O.
CLOSING
41
6
N.C.
OPENING SAFETY
41
8
N.C.
REVERSAL SAFETY CONTACT With DIP3=OFF the opening of the contact during the closure manoeu-
1
9
N.C.
STOP
1
28
N.O.
BLOCK EXCLUSION
1
29
N.O.
POWER RESET
27
3A
N.O.
SIDE A PARTIAL OPENING
27
3B
N.O.
SIDE B PARTIAL OPENING
2.2 Autocontrolled safety devices
Command
1
6
N.C.
OPENING SAFETY
1
8
N.C.
REVERSAL SAFETY CONTACT The opening of the contact during the closure manoeuvre causes the
41
SAFETY TEST
Function
A permanent contact enables the automatic closing. Selector switches
COMH-K and COME automatically select the automatic closing.
The opening manoeuvre starts when the contact is closed.
The closing manoeuvre starts when the contact is closed.
With DIP3=OFF the opening speed is reduced in the last 500 mm of the
door stroke when the contact is opened.
vre causes the movement to invert (opening).
All movements are stopped when the contact is opened. All normal or
emergency operations are excluded when the contact is opened.
Warning: when the contact closes again the door proceeds with the
interrupted manoeuvre.
The block operation is excluded when the contact is closed.
The exclusion is automatic in the fully open and partial two-way posi-
tions with COMH, COMK and COME.
All acquired data is annulled when the contact is closed.
The automation can start acquisition again after 3 seconds.
Partial opening occurs when the contact is closed.
Function
The opening speed is reduced in the last 500 mm of the door wing stro-
ke when the contacts are opened.
movement to invert (opening).
With DIP3=OFF connect terminal 41 of the control panel to the corre-
sponding test terminal on the safety device. Terminal 41 activates a test
of the safety device on each cycle. If the test fails the SA led flashes and
the test is repeated.
Description
Description
9
GB