Operation of pressure vessels
• Anyone who operates a pressure vessel must keep
this in good working order, operate and monitor it
correctly, perform the necessary maintenance and
servicing works immediately and implement safe-
ty measures as required according to the circum-
stances.
• The regulatory authority can instruct necessary
monitoring measures in individual cases.
• A pressure vessel must not be operated if it exhib-
its a defect that poses a danger to personnel or
third parties.
• Check the pressure vessel for rust and damage
each time before use. The compressor shall not be
operated if the pressure vessel is damaged or rusty.
If you discover damage, please contact the custom-
er service workshop.
Warning! This power tool generates an electromagnet-
ic field during operation. This field can impair active or
passive medical implants under certain circumstances.
In order to prevent the risk of serious or deadly injuries,
we recommend that persons with medical implants
consult with their physician and the manufacturer of
the medical implant prior to operating the power tool.
Store the safety instructions safely.
6. Residual risks
The machine has been built according to the state-of-
the-art and the recognised technical safety require-
ments. However, individual residual risks can arise
during operation.
• Health hazard due to electrical power, with the use
of improper electrical connection cables.
• Furthermore, despite all precautions having been
met, some non-obvious residual risks may still remain.
• Residual risks can be minimised if the "Safety In-
structions" and the "Intended Use" together with the
operating manual as a whole are observed.
• Avoid accidental starting of the machine: the oper-
ating button may not be pressed when inserting the
plug in an outlet. Use the tool that is recommended
in this operating manual. This is how to ensure that
your machine provides optimum performance.
• Keep your hands away from the working area when
the machine is in operation.
7.
Technical data
Mains power connection
Engine output
Operating mode
Compressor speed
Pressure vessel volume
Operating pressure
Theo. Suction capability
Theo. Power output
Protection category
Device weight
Max. installation altitude
(above sea level)
Subject to technical changes!
Noise and vibration
m Warning: Noise can have serious effects on your
health. If the machine noise exceeds 85 dB, please
wear suitable hearing protection.
Noise data
Sound power level L
Sound pressure level L
Uncertainty K
The noise emission values have been determined in
accordance with EN ISO 3744:1995.
Note: The total vibration emission values specified
and the device emissions values specified have been
measured in accordance with a standardised test pro-
cedure and can be used for comparison of one electric
tool with another.
Note: The total vibration emission values specified and
the device emissions values specified can also be used
for an initial estimation of the load.
Warning: The vibration values and noise emission
values can vary from the specified values during the
actual use of the electric tool, depending on the type
and the manner in which the electric tool is used, and in
particular the type of workpiece being processed.
www.scheppach.com
approx. 162 l/min
approx. 100 l/min
approx. 11.7 kg
85 dB
WA
67.4 dB
pA
3 dB
wa/pA
230 V~ 50Hz
1100 W
S1
2,850 rpm
approx. 6 l
approx. 8 bar
IP 30
1000 m