Herunterladen Inhalt Inhalt Diese Seite drucken

Post-Installation Check - ACS Vibrocont SHM-300 Bedienungsanleitung

Vibrationsgrenzschalter für flüssigkeiten im lebensmittelbereich
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

View, dimensions in mm (in)
5.3

Post-installation check

Is the device undamaged (visual inspection)?
m
Does the device conform to the measuring point specifications?
For example:
• Process temperature
m
• Process pressure
• Ambient temperature
• Switch point
Are the measuring point identification and labeling correct (visual inspection)?
m
Is the device adequately protected from precipitation and direct sunlight?
m
Is the device secured properly?
m
54
54
ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de
Description
Tri-Clamp ISO2852 DN25-38 (1 to 1 ½")
47.9 (1.9)
DIN32676 DN25-40
Tri-Clamp ISO2852 DN40-51 (2")
DIN32676 DN50
Pressure and temperature (maximum):
+25 bar (+362 psi) at +150 °C (+302 °F)
NOTICE
A0022035
Flush-mounting in weld-in adapter RD52, tuning fork can be
47.9 (1.9)
aligned
With silicon seal and slotted nut
Pressure and temperature (maximum):
• +25 bar (+362 psi) at +150 °C (+302 °F)
• +40 bar (+580 psi) at +100 °C (+212 °F)
A0022038
Pay attention to the temperature and pressure specifications
for the seals and clips used at the customer site.