Herunterladen Diese Seite drucken

everActive UC-4200 Bedienungsanleitung Seite 11

Vorschau ausblenden Andere Handbücher für UC-4200:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

improvement the cell is worn
out and may be used only in low
power devices, but it is
recommended to dispose such
battery,
>500 mΩ - it is recommended
to run refresh cycles and check
the value again. If there is no
improvement the cell is
completely worn out and should
be disposed,
To make sure the obtained IR results are valid, make sure
the contacts / metal parts of the charger and battery are clean. It
is recommended to make few measurements – if the value is
repeatable it can be considered as valid. It is always good to
have a reference battery of the same type, with known low IR
value to compare the results.
9. Charge mode.
The charger has six independent charging slots. It allows to
charge different cells, sizes, capacities in different (from 1pc to
6pcs) quantity at the same time. All compatible batteries are
automatically charged (except the LiFePO
have to be selected manually). The charge process is strictly
controlled and terminated with very good precision (the
termination method depends on battery type). When the
operation is finished, the full battery symbol is visible next to
corresponding slot number. Finished process is also indicated
by 'End' label on LCD when showing the status of selected
battery slot. Each battery status can be reviewed by pressing
SLOT button. The display shows a wide variety of information:
very high result for a Li-based
16340/18650/21700 cell – being
one of these the cell should be
disposed.
and Li-HV, which
4
11

Werbung

loading