Herunterladen Inhalt Inhalt Diese Seite drucken

Fronius CL 44.4 Delta Serviceanleitung Seite 93

Netzgekoppelter wechselrichter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

508
The area of the internal memory for the "Inverter number" is incomplete
Cause:
One-time - memory error
Remedy:
Remedied automatically
Cause:
Multiple occurrences - EE-PROM "Inverter number" in the IG BRAIN PC
board defective
Remedy:
Replace IG BRAIN
Cause:
Multiple occurrences - EE-PROM "Inverter number" in the IG BRAIN PC
board faulty
Remedy:
Update software
509
24 hours no feed-in mode
Cause:
Heavily soiled or snow-covered solar modules
Too little energy from the modules for feed-in mode
Remedy:
Remove snow or clean solar modules
Cause:
Fronius CL hardware defect
Remedy:
Check other service codes and, if necessary, replace PC board / power stage
set
Cause:
Starting DatCom system for the first time
Remedy:
Operate device without monitoring and read error codes
-> Error 509 can only be displayed in connection with a datalogger
510
Solar Net self diagnostic system detected errors
Cause:
One-time - memory error
Remedy:
Remedied automatically
Cause:
Memory in IG BRAIN defective
Remedy:
Replace IG BRAIN
Cause:
Inverter hardware defect
Remedy:
Operate device without monitoring and read error codes
->This error can only be displayed in connection with a datalogger
-> The error STATE 509 cannot be displayed until the next connection - 24-
hour interval invalid
511
Fronius Sensor Card self diagnostic system detected errors
Cause:
One-time - memory error
Remedy:
Remedied automatically
Cause:
The memory in the IG BRAIN is defective
Remedy:
Replace IG BRAIN
-> This error can only be displayed in connection with a datalogger and a sen-
sor card/box
-> The LCD display for the sensor values has been reset
91

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis