535
Fan defect detected during self test
Check the STATE FAN setup menu to determine which fans are affected
Cause:
Fan blocked
Remedy:
Make sure fan is free of any obstructions
Cause:
Fan not connected
Remedy:
Check plug connection
Cause:
Ambient temperature too high
Remedy:
Increase supply air intake
Cause:
Fan defective
Remedy:
Replace fan
Cause:
Measurement error in Snowball PC board
Remedy:
Replace Snowball
536
Fan defect detected during operation or target speed not reached
Fan defect during operation, door fans will resume operation after the DC reset is carried
out
Check the setup menu STATE FAN to determine which fans are affected
Cause:
Fan blocked
Remedy:
Make sure fan is free of any obstructions
Cause:
Fan not connected
Remedy:
Check plug connection
Cause:
Ambient temperature too high
Remedy:
Increase supply air intake
Cause:
Fan defective
Remedy:
Replace fan
Cause:
Measurement error in Snowball PC board
Remedy:
Replace Snowball
95