Herunterladen Inhalt Inhalt Diese Seite drucken

Temporary Error; Abnormal Behavior - Fronius CL 44.4 Delta Serviceanleitung

Netzgekoppelter wechselrichter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Temporary error

Abnormal behav-
ior
102
YES
Inverter error unlikely
(check grid, solar modules)
See Fronius service code for details
List
- When does the error occur and since when has it been occurring?
- How many devices are affected?
- Details about solar modules (strings, module grounding,
type of installation)
- Details of cabling (DC and AC)
- Hardware and software version
YES
Activate event logging
Connection type and telephone number
or IP address
Contact Fronius TechSupport
When does the error
occur?
- Check grid
- Check TOTAL (IN) menu
- Check Error Counter (IN)
- Check grid parameters (IN)
Are other devices also
showing the error?
(PC board / inverter must be repaired)
Fronius DATCOM
installed?
Contact Fronius TechSupport
NO
Inverter error unlikely
See Fronius service for details
code list
NO

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis