Error
Cannot dispense
carbonated water
Cold water not cold
enough
Water contains too little
CO
2
When the CO 2 button
is pressed, only CO 2
escapes
Flashing light at the water
outlet
Water leakage
UV LED indicator flashes
on the control panel, an
acoustic alarm sounds
and water cannot be
dispensed
Cause
CO 2 On/off switch
on the rear panel is
switched off
CO 2 pressure is too high Close the CO 2 gas cylinder and relieve the
Thermostat is not set
correctly
CO 2 gas cylinder is
empty
CO 2 tank must be
vented
Pump does not react
Wastewater tank is full
Leakage sensor is acti-
vated
Water pipes in the device
are defective
UV lamp is not connected
properly or is defective
Error recovery
Switch the CO 2 On/off switch to On
pressure using the pressure regulator. Press and
hold the selection button for CO 2 and allow the
water to drain off in order to relieve the pressure
in the carbonator. Release the selection button
for CO 2 when no more carbonated water flows
out. Open the CO 2 gas cylinder again and set the
pressure to 3 bar. Press the selection key for CO 2
water until carbonated water is dispensed.
Check the thermostat and, if necessary, reduce the
temperature
Replace the CO 2 gas cylinder.
Turn off the water and actuate the CO
only gas escapes. Then turn on the water again and
allow the CO
to refill
2
Disconnect the device from the power supply for 30
seconds and reconnect and press the CO
Empty the wastewater tank
Contact a service technician
Close the water tap, disconnect the device from the
power supply, then contact a service technician
Disconnect the device from the power supply and
unplug the connection; plug it back in, then switch
the device on again. If the UV lamp does not work,
then disconnect the device from the power supply
again and replace the UV lamp. It is essential to
observe the warnings, see Section 6.4.
EN
outlet until
2
key again.
2
26