Installation guide / Montageanleitung
15. DANFOSS ICON2 ADVANCED MASTER CONTROLLER (CONTROL)
ENGLISH - EN
Please power o the ICON2 Advanced Master Controller when
during the installation!
Wiring need to done by authorized electrician!
Do not forget the GROUNDING!
ENGLISH - EN
It is possible to connect up to 15 room thermostats wireless
(Zigbee) or wired.
The ICON2 Advanced Master Controller is con gured via the
ICON2 app which can be connected via bluetooth. All thermostats
are also connected in the ICON2 app.
After con guration, the installer can generate a PDF report for the
customer via the ICON2 app.
15 thermostats can be connected to the three wired inputs, as the
thermostats have their own MAC address.
AN42465492604301-010201
UnoFloor Mixing Comfort/Contol
DEUTSCH - DE
Die elektrische Verdrahtung muss bei ausgeschalteter Spannungs-
versorgung erfolgen!
Die Verdrahtung darf nur von autorisierten Elektroinstallateuren
durchgeführt werden!
Erdung nicht vergessen!
DEUTSCH - DE
Es ist möglich, bis zu 15 Raumthermostate drahtlos (Zigbee) oder
kabelgebunden anzuschließen.
Der ICON2-Advanced Master Controller wird über die ICON2-App
kon guriert, die über Bluetooth verbunden werden kann. Alle
Thermostate werden auch in der ICON2-App verbunden.
Nach der Kon guration kann der Installateur über die ICON2-App
einen PDF-Bericht für den Kunden erstellen.
An die drei kabelgebundenen Eingänge können 15 Thermostate
angeschlossen werden, da die Thermostate über eine eigene
MAC-Adresse verfügen.
© Danfoss | 2025.01 | 20