Installation guide / Montageanleitung
12. HEAT UP / AUFHEIZEN
ENGLISH - EN
If no mains power for heat up period (screed drying) do not re-
move red mounting split!
Heat up the installation with TWA open, do not remove the retain-
ing ring on the actuator!
Plastic heat meter insert is not for permanent operation! Please
exchange in case no heat meter is mounted!
13. FTC TEMPERATURE CONTROLLER / FTC TEMPERATURREGLER
ENGLISH - EN
FTC is a self-acting thermostatic sensor used for flow temperature
control of floor heating.
The water temperature is measured by a surface sensor. The snap-
lock connector of the sensor element secures a firm connection
to the valve.
Features:
• Closes on rising sensor temperature.
• Temperature range: 15 °C to 50 °C
For the UnoFloor Mixing Control, the FTC temperature
controller has been replaced with a 24V TWA, which is controlled
by the ICON2 Advanced Master Controller.
AN42465492604301-010201
UnoFloor Mixing Comfort/Contol
DEUTSCH - DE
Wenn zum Aufheizen keine Netzspannung vorhanden ist (Es-
trichtrocknung), roten Sicherungsring nicht entfernen!
Anlage bei geö netem TWA Stellantrieb erwärmen, Sicherung-
sring am Antrieb nicht entfernen!
Wärmezählerpassstück ist nicht für den Dauerbetrieb geeignet!
Austauschen, falls kein Wärmezähler montiert wird!
DEUTSCH - DE
Der FTC ist ein selbsttätiger thermostatischer Fühler für die
Regelung der Vorlauftemperatur von Fußbodenheizungen.
Ein Anlegefühler misst die Wassertemperatur. Die Schnappbefesti-
gung des Fühlers sorgt für einen festen Anschluss an das Ventil.
Merkmale:
• Schließt bei steigender Fühlertemperatur.
• Temperaturbereich: 15 °C bis 50 °C.
Bei der UnoFloor Mixing Control wurde die FTC Temperaturregler
durch eine 24V TWA ersetzt, die vom ICON2 Advanced Master
Controller gesteuert wird.
© Danfoss | 2025.01 | 16