Herunterladen Inhalt Inhalt Diese Seite drucken

Whirlpool K 140 ES.C/I Installation Und Gebrauch Seite 17

Gasherd mit gasbackofen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 58
remove the knob and adjust the regulation screw, which
is positioned in or next to the tap pin, until the flame is
small but steady.
N.B.: in the case of liquid gas, the regulation screw
must be screwed in to the bottom.
check that the flame does not turn off when you turn
the tap quickly from high to low.
d Regulating the primary air of the burners:
The primary air of the burners requires no regulation.
Table 1
Burner
Diameter
(mm)
Fast
100
(Large)(R)
Semi Fast
75
(Medium)(S)
Auxiliary
55
(Small)(A)
Nominal (mbar)
Supply
Minimum (mbar)
Pressures
Maximum (mbar)
*
At 15°C and 1013 mbar- dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
***
Butane
P.C.S. = 49,47 MJ/Kg
Natural
P.C.S. = 37,78 MJ/m
Burner and nozzle characteristics
Thermal Power
By-Pass
kW (p.c.s.*)
1/100
Nominal Reduced
(mm)
3.00
0.7
41
1.90
0.4
30
1.00
0.4
30
3
Important
On completion of the operation, replace the old rating
sticker with one indicating the new type of gas used. This
sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in
compliance with current National Regulations relative to
"regulators for channelled gas".
Liquid Gas
Nozzle
Flow*
1/100
g/h
(mm)
***
86
218
70
138
50
73
28-30
20
35
S S
A
R
K 140 ES.C/I
17
Natural Gas
Nozzle
Flow*
1/100
**
(mm)
214
116
286
136
106
181
71
79
95
37
20
25
17
45
25
l/h

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis