Instructions for mounting / schematic
4.2 Blind hole shaft / Hollow shaft
The following instructions are not exhaustive as the assembly situation may be different for each
application.
4.2.1 Mounting of the clamping ring (general)
➢ Dimensions and individual mounting options can be found in the customer-specific drawing.
➢ The measuring system must be mounted on a grease-free shaft.
➢ Axial slippage of the measuring system on the drive shaft must be prevented by fixing the
clamping ring.
If necessary, further measures are required to prevent axial slippage of the measuring
-
system.
➢ Radial slippage (slip) of the measuring system on the drive shaft must be prevented by positive
locking using a key / keyway combination.
➢ The clamping of the measuring system must not be axially loaded.
➢ The screw of the clamping ring must be tightened to 2 Nm using a torque wrench and secured
against unintentional loosening using medium-strength thread locker.
4.2.1.1 Requirements for the customer shaft
Force
Series
transmission
with
positive locking
C_H582
without
positive locking
with
positive locking
C_S582
without
positive locking
with
positive locking
C_H802
without
positive locking
with
positive locking
C_H1102
without
positive locking
See the accompanying drawings below.
TR Electronic GmbH 2023, All Rights Reserved
Page 46 of 55
Customer connection
with torque holder (TH) [mm]
X1
X2
X3
10,4
1,6
min. 77
-0,2
/
/
min. 77
10,4
1,6
32,5
-0,2
-0,1
/
/
32,5
-0,1
10,4
2
min. 66
-0,2
/
/
min. 66
+0,2
5
3
min. 85
-0,1
/
/
min. 85
TR-ECE-BA-DGB-0175 v01
Customer connection with
flange ring pin/groove (FRPG) [mm]
X4
Y1
Y2
Y3
/
6
1,6
min. 77 23
-0,2
-0,2
/
/
/
min. 77 23 max. 56
/
6
1,6
min. 35 23
-0,2
-0,2
/
/
/
min. 35 23 max.16
+0,2
11
5
2
min. 66 30
-0,2
11
/
/
min. 66 30 max. 47
+0,2
11
12
3
min. 85 46
-0,1
11
/
min. 85 46
Y4
Y5
Y6
/
/
/
/
22
-1
/
/
53
-0,5
/
+0,2
/
5
+0,2
/
5
Printed in the Federal Republic of Germany
10/24/2023