The device is in good condition or has only minor damages: it is
therefore suitable for use.
The device has medium/major damages that affect its primary
functions and, as a consequence, must be discarded.
The device has defects that can be solved through lubrication or
cleaning. If such defects are not solved, the device must be
discarded.
The device has defects.
DEVICE PERIODIC CHECK SHEET
1)
Known product history
1.1
Check the existence and the readability of the marking details。
1.2
Check that device has not exceeded the storage and/or in-use lifetime,
as stated in the specific instructions for use.
1.3
Check that the device is intact and no parts are missing (check against a
new product).
1.4
Check that the device has not been modified outside the factory or
serviced in a non-approved centre (check against a new product).
1.5
Any PPE showing unexpected degradation should be quarantined,
pending a detailed inspection. The user should:
- Provide precise information on the usage conditions.
- Report any exceptional event regarding his PPE. (Examples: fall or fall
arrest, use or storage at extreme temperatures, modification outside
manufacturer's facilities...).
2) Checking the condition of the sheath
2.1
Check the condition of the sheath over the full length of the rope. Make
sure there are nocuts, burns, frayed strands, fuzzy areas, or signs of
chemicals...
3) Checking the condition of the core
3.1
Do a tactile inspection of the core over the full length of the rope, as
indicated in the drawing. This allows you to detect areas where the core
is damaged (hard spots, swelling, soft or crushed areas...).
4) Checking the condition of the core
7