2. Press „button 1" on the receiver 7 x quickly (within max. 7
seconds)
3. The status LED flashes 7 x quickly and thus confirms that all
coupled transmitters have been deleted from the receiver's
memory.
6. ERROR CODES AND REMEDY
In the event of system malfunctions, the error that has occurred
is given by a flashing sequence (see "LED status" section) of the
respective LEDs. The corresponding error can be diagnosed using
the following list and (where possible) remedied.
Flashing
Error
sequence
2 x short
Receiver undervoltage
(< 6.5V for > 1500ms)
3 x short
Receiver overvoltage
(> 36V for > 60ms)
4 x short
Receiver temperature
exceeded (> 85°C)
1 x long,
Receiver output 1
1 x short
(> 3.5A for > 1000ms)
1 x long,
Receiver output 2
2 x short
(> 3.5A for > 1000ms)
1 x long,
Receiver output 3
3 x short
(> 3.5A for > 1000ms)
1 x long,
Receiver output 4
4 x short
(> 3.5A for > 1000ms)
Solution
Check and if necessary, increase
the power supply of the receiver.
Check and if necessary, reduce
the power supply of the receiver.
Disconnect the receiver's power
supply and leave the receiver
to cool.
Check and reduce the current
consumption of the connected
component.
Check and reduce the current
consumption of the connected
component.
Check and reduce the current
consumption of the connected
component.
Check and reduce the current
consumption of the connected
component.
EN