19.
Faults
and
Problem
Noreception ofthe thermal/
hygrosensors.
(Dashes in the display)
The combi sensor is not received
Toohighortoo lowtemperature
values.
Absolute air pressure doesnot
match the information from wea-
therservices for yourlocation.
Raingauge shows rain despite
drought.
Windvanealwaysfallsin the
sameposition duringno or light
wind.
Data is not transferred to a
weatherportal.
NoWiFi connection
20. Technical
Temperature:
Indoor climate sensor:..........................................................
Combi sensor:..
Air humidity:
Indoor air humidity:.
Outdoor air humidity:
Air pressure:
Measuringrange:................................................................300—1100 hPawith 0,1 hParesolution
Accuracy:.... .
90
Errors
Lösung
Too far awayfromthe basestation(freefield100m max.)or shielding obstacles such
asmetalparts,walls,reinforced cellarceilings etc.
- It canhelpto move the sensorslightlyin the roomto establish a connection.
- Observe the noteson radioreception in chapters4 & 12.
- Insert new batteries and register the sensor again,see chapter 11.
Position the basestationawayfromsources of interference, e.g.computers, electrical
machines,other radio transmitters etc.
- Sourcesof error such asthe above.Tryto reducethe distanceof the basestation to the
sensor and exclude sources of interference.
Check whetherthetransmitterLEDonthe bottomofthe sensor(seechapter 4) lights
up every16s. If not,restartthesensor w ith a reset(seechapter 4)andregisterit again
atthe basestation(seechapter 11).
- Ifthefaultpersists, restart t he base stationbypressing theresetbutton(forlocation, s ee
chapter 3) with a pointedobject,remove the powersupplyplugfromthe basestation,
holddownthe resetbuttonandpluginthe powersupplyplugagain. A fterthis,release
the reset button and wait for the station to start.
Observe the location selection information in chapter 4 anddo not install s ensors near
heatsources. D onotplacetheoutdoor s ensor n earheatradiating or reflecting wallsetc.
Toolowtemperature valuescan occurif the sensoris in thecoolingair flow fromfans
or air conditioners.
Makesurethat the absolutepressure is shownfor comparison, not the relativeair
pressure.
- Calibrate the air pressure sensoraccording to chapter10.
Check whether thecombisensor i s mechanically s table. I t mustnot move andmustbe
installed exactlyin linewith the integrated spirit level.
- Check whether the raingauge's seesaw is inthe bearings on bothsides.
- Check whether the password andthe stationIDarecorrect.
Observe the general e rrormessages a t the endof chapter 8.
- Check the WLAN settings according to chapter 7.
Specifications
........................ ..-40 to +60 oc with 0,1 oc resolution, accuracy ±1 oc
-100 to +60 oc with 0,1 oc resolution
..... ... ..10—99 % with 1 % resolution
.. ..10—99 % with 1 % resolution, accuracy ±5 %
..±3
hPa 700-1100
hPa