Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Honeywell HS10S Einbauanweisungen

Vorschau ausblenden Andere Handbücher für HS10S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
9.4. Cleaning
Caution !
Do not use any cleansers that contain solvents and/or
alcohol for cleaning the plastic parts, because this can
cause damage to the plastic components - water
damage could result.
1. Close shutoff valve on inlet
2. Release pressure on outlet side (e.g. through water tap)
3. Close shutoff valve on outlet
4. Unscrew filter bowl
• Use double ring wrench ZR10K
5. Remove filter, clean and reinsert
6. Place O-ring onto filter bowl
7. Slowly open shutoff valve on inlet
8. Slowly open shutoff valve on outlet

11. Troubleshooting

Problem
Water is escaping from the spring
bonnet
Too little or no water pressure
The outlet pressure set does not
remain constant
MU1H-1101GE23 R0612
GB
10. Disposal
• Dezincification resistant brass housing
• Brass shutoff valve and connectors
• High grade synthetic material check valve cartridge
• Stainless steel fine filter
• Red-bronze or shock-resistant, clear transparent synthetic
• High-quality synthetic material spring bonnet
• High-quality synthetic material valve insert
• Fibre-reinforced NBR diaphragm
• NBR seals
Cause
Diaphragm in valve insert is faulty
Shut-off valves upstream or downstream
from domestic water station not fully open
Pressure reducing valve is not set to the
desired outlet pressure
Filter mesh dirty
Domestic water station not mounted in the
direction of flow
Filter mesh dirty
Valve insert, sealing ring or edge of nozzle
is contaminated or worn
Rising pressure on outlet (e.g. in boiler)
10
material filter bowl
Observe the local requirements regarding correct
waste recycling/disposal!
Remedy
Replace valve insert
Open the shutoff valves fully
Set outlet pressure
Reverse rinsing
Fit pressure reducing valve in flow direction
(note direction of arrow on housing)
Reverse rinsing
Replace valve insert
Check check valve, safety group etc.