10. Troubleshooting

Disturbance
Beating sounds
Water is escaping from the spring
hood
Too little or no water pressure
The outlet pressure set does not
remain contant but rises conti-
nuously
MU1H-1126GE23 R1004
GB
Cause
Filter combination is too
large
Diaphragm in valve insert is faulty
Shutoff valves up- or downstream of
the filter combination are not fully open
Filter combination is not set to the
desired outlet pressure
Filter insert in filter combination is con-
taminated
Filter combination is not fitted in flow
direction
Mesh is contaminated
Mesh is contaminated or worn
Valve insert, sealing ring or edge of
nozzle is contaminated or worn -
unwanted rise above set pressure
Rising pressure on oulet (e.g. in boiler)Check non-return valve, safety group
10
Remedy
Call our Technical Customer Ser-
vices on +49 (0) 18 01 46 63 00
Replace valve insert
Open the shutoff valves fully
Set outlet pressure (☞ chapter 7)
Clean or replace filter insert
(☞ chapter 9)
Fit filter combination in flow direction
(note direction of arrow on housing)
Clean or replace mesh
Clean or replace mesh
Replace valve insert
etc.