3.4. POWER SUPPLY
The C.A 771 is powered by two 1.5 V alkaline batteries (type AA or LR6).
The battery life provides 5000 ten-second measurements.
The batteries can be replaced with rechargeable accumulators, but these will not
last as long.
3.5. BUILD CHARACTERISTICS
Dimensions (L x W x D)
„ of the device
„ of the test probe
Mass
350 g approx.
Cable
length 1 m
Protection rating
„ IP 65 according to IEC 60529
„ IK 06 - 1J - Eha pendulum hammer method according to IEC 50102
Drop test
2 meters.
3.6. COMPLIANCE WITH INTERNATIONAL STANDARDS
Two-pole voltage detector EN 61243-3 Ed. 2 dated 2010.
The device is in conformity with IEC-61010-1 1000V, CAT IV.
3.7. ELECTROMAGNETIC COMPATIBILITY
Emission and immunity in industrial environment according to IEC 61326-1.
228 x 60 x 39 mm
218 x 35 x 25 mm