Test/SiIence
Button
The Test/SiIencebutton is used to test the unit's electronics and to silence the unit during an alarm.
Short pressthe test button and you will hear a short beep, indicating that the alarm has entered the test mode. Pleaserefer to
the "AlarmTesting" section for further information. The alarm goes back to the standby mode after testing.
NOTE:After a test has begun, the alarm will sound and the LED indicator will flash red. This does not indicate that
CO is present.
CO Alarm
Levels
This X Sensecarbon monoxide alarm is programmed to sound an alarm at the fol owing CO concentrations within the time
periods listed:
30 ppm over 120 minutes,
50 ppm for 60-90 minutes,
100 ppm for 10—40 minutes,
and 300 ppm for 0—3minutes.
When CO is detected and the alarm sounds, the COconcentration wil be displayed on the LCDand a blue backlight will be lit.
The LEDindicator will flash red and the alarm will issue4 short beeps,repeating the cycleevery 5.8 seconds.
• 04 •
CO Concentration
and Symptoms
The table below showsthe effects of different levelsof COpoisoning on the body:
Parts per Million (PPM)
Effects
on Adults
Slight headache,nausea,fatigue (flu like symptoms).
100
Dizziness
and headache
200
Nausea,frontal headache,drowsiness,confusion and rapid heart rate.
Riskto life after over 3 hours of exposure.
Severeheadaches,convulsions,vital organ failures. Death possiblewithin 2-3 hours.
A WARNING
THIS
DEVICE
IS DESIGNED
TO PROTECT
INDIVIDUALS
NOT FULLY SAFEGUARD INDIVIDUALS WITH SPECIFIC MEDICAL CONDITIONS. IF IN DOUBT, CONSULT A MEDICAL
PRACTITIONER.
within
2-3
hours,
FROM ACUTE
EFFECTS OF CARBON
MONOXIDE
EXPOSURE.