x-sense XC01-M Bedienungsanleitung Seite 15

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

For devices
connected
to the
base
station:
• When an alarm is triggered, an in-app messagewill appear and an alarm push notification will be sent to your smartphone.
• When one alarm is triggered, all devicesconnected to the system and the basestation WIIIsound an alarm simultaneously.
• The basestation will automatically mute after 10 minutes of continuous alarm. After the basestation stops the alarm, al
devices in the interconnected systemwill still alarm.
• In the case that the basestation powers off and is disconnected from the network, all devices arestill interconnected, sowhen
one alarm is triggered, al will go off
• Thevolume level of the base station is adjustable. The alarmsand base station can be remotely muted through the app. An
app push notification will be sent to your phone when the CO concentration drops be ow the alarm threshold.
CO Alarm
Precaution
Dangerous CO concentration is detected, but has not reached the alarm status.The app will show a "COAlarm Precaution'
message,and an app push notification wil be sent to your smartphone. Potential dangerous CO conditions exist.
1. If the Initiating
Unit is Triggered by Smoke:
When one smoke alarm is triggered in the interconnected network, the unit wil beep 3 times, paired with the LEDthat flashes
red every4 seconds.Any other units in the network will follow suit—they will beep 3 times every4 seconds, paired with the
LEDflashing red and green in succession.
• 26 •
2. If the Initiating
Unit is Triggered
by CO:
When one COalarm is triggered in the Interconnected network, the unit will beep 4 times every 5.8 seconds, paired with the
LEDflashing recl Any other units in the network will follow suit—they wil beep 4 times every 5.8 seconds,paired with the LED
that tlashes red 4 times first,fol owed by the LEDthat tlashes green once with every beep. When the CO concentration evel
drops below the alarm threshold, the alarm will cease.
NOTES
• When one unit is triggered, other interconnected units will sound. If the smoke alarm and CO alarm are triggered in
the network at the same time, the alarm signal of the smoke alarm will take priority over that of the CO alarm.
• This alarm has a relay function that extends the wireless interconnected network for wide detection coverage.
Silence
Mode
f there is a false alarm, you can temporarily silence it by pressing the test/silence button on the device or tapping the silence
button in the app. The LEDwill flash red4 times every 5.8 seconds to remind you that the alarm has been silenced.Thealarm
will automatica ly exit silence mode after 9 minutes,
During silence mode, if the carbon monoxide concentration is still greater than 50 ppm after 6 minutes, the device wil be
triggered again; if not, the device will automatically exit the silence mode after 9 minutes, and the LEDwill flash green 3 times
continuous y. f the COconcentration is above 300 ppm, the silencefunction cannot be enabled.
27 •