Alarm (warning, compressor continues to run)
ALARM: OIL FILT
ALARM: SEPARATOR
ALARM: AIR FIL
ALARM: OIL CHANG
ALARM: GREASE M1
ALARM: BELTS
ALARM: T --.-.°C
STOP:T LOW --.-.°C
Alarms for maintenance are triggered at the set time before maintenance. The alarm message is
displayed intermittently and repeatedly in the case of an overrun maintenance interval.
Error messages (compressor stops or does not start)
ERROR STOP
STOP: M1 OVERLD
--.-. A
STOP: M1 SHORT
--.-. A
STOP: FAN OVERLD
--.-. A
STOP: FAN SHORT
--.-. A
STOP: PH. MISS
STOP: PHASE UNBL
STOP: P HIGH
--.- bar
STOP: FAN PHASE
STOP: FAN UNBL
STOP: EMERG STOP
The controller saves the last 5 errors.
22
Maintenance interval exceeded
Maintenance interval exceeded
Maintenance interval exceeded
Maintenance interval exceeded
Maintenance interval exceeded
Maintenance interval exceeded
T Oil/air mixture temperature at the compressor outlet high.
The ambient temperature is too low. The compressor start is disabled.
Current consumption main motor too high
Short circuit on the main motor
Current consumption fan motor too high
Short circuit on the fan motor
Phase error main motor
Phasedisbalance at the main motor
Permissible operating pressure exceeded
Phase error fan motor
Phasedisbalance at the fan motor
Compressor does not start. EMERGENCY STOP button pressed
Restarting operation without eliminating the cause of the fault
isnot permitted!