Installation instructions, only for experts
To install the safety shut-off device, perform the following steps:
1. Install the safety shut-off device in accordance with the operating instruc-
tions for the device.
2. Guide the wires for the safety shut-off device through the cable bushing
into the low-voltage connection area
3. Connect the wires to the terminals labelled "OSG" in terminal strip
5.7. Remote start
This is connected using terminals "S", "B" and "C". "S" stands for sauna mode.
"B" is a +24 V DC output. This must be activated using a switch or an actuator
on terminal "S".
5.8. Finishing installation
1. Connect the earth conductor for the power supply cable and all devices to
g
the earth rail
2. Place the cover of the housing on the upper edge of the junction box.
3. Push the clip locks inwards lightly, and turn the cover of the housing down-
wards until it engages audibly.
WORLD OF WELLNESS
.
1
.
p. 17/30
6
2
.
EN