LEAKSHIELD
Measure fill level:
Measure fill level:
Measure fill level:
Measure fill level:
•
Deaerate system:
Deaerate system:
Deaerate system:
Deaerate system:
•
Refill system:
Refill system:
Refill system:
Refill system:
•
Depending on the currently selected action, the further display of the lower area of
this page changes.
In SHIELD and MONITOR mode, the middle area shows a diagram with the cur-
rent negative pressure and information on the minimum necessary negative pres-
sure, the current setpoint and the maximum negative pressure.
Below this is a diagram showing the pump running time per day. This serves as a
simple indicator for minor leakages. Tight systems should have a pumping time of
less than 15 seconds per day on average.
Upon completion of an action, LEAKSHIELD automatically returns to the previously
selected mode.
When starting up, first call up the settings wizard. You activate this by clicking on
the gearwheel at the very top right in the title bar.
11.1.
11.1. The settings wizard
The settings wizard
11.1.
11.1.
The settings wizard
The settings wizard
After calling up the wizard, a selection first appears in which you can choose be-
tween the wizard for the basic setting and an editing of the current setting. For
commissioning, leave the first preselected option selected and use the right arrow
to call up the next dialog.
In the reservoir dialog, select the reservoir you are using.
LEAKSHIELD needs this information to be able to determine the fill level correctly
and e. g. to be able to calculate the volume change properly.
For Aqua Computer products, you can select the reservoir used directly from the
drop-down selection field. For other reservoirs, you can enter user-defined values
manually.
Settings for total volume, the remaining air volume at maximum fill level as well as
at minimum fill level have to be made.
In addition, there is the option to measure the fill level automatically on a regular
basis. If this action is activated, LEAKSHIELD will measure the level regularly when
changes are made to the system (e. g. opening the reservoir) and after certain
times.
- 16 -
Measure the level in the reservoir.
Supports the venting of the system during filling
Suck coolant into the system