Tab. 1:
Status messages
normal operation
A
Function and operation
Light signals
There is a signal lamp in the outer fitting. The signals and their meanings are
explained in the following table.
Signal
yellow
green
red
red red red
yellow yellow yellow
red 5 seconds red 5 seconds red
Overload coupling (Premium variant)
Attention!
Risk of destruction due to striking of the handle: The fitting can be destroyed if
the handle strikes against the wall. The risk is avoided by installing a door stopper.
Overload coupling can release: The overload coupling is released when
∙ one handle is blocked and
∙ the other handle is actuated by force.
The overload coupling remains permanently released.
Engage the overload coupling again:
1
Remove the blockage of the door handle.
2
Actuate the handle several times properly.
� The overload coupling engages again.
� The fitting is now operational again.