INSTALLATION

Commissioning

10. Commissioning
WARNING ELECTROCUTION
Commissioning may only be carried out by a qualified
contractor in accordance with safety regulations.

10.1 Initial start-up

Material losses
!
The high limit safety cut-out will respond if you fail to
follow the correct sequence (first water, then power).
Proceed as follows:
f Replace the temperature controller.
f
f Make the high limit safety cut-out operational by
f
pressing the reset button (see chapter "Installation /
Troubleshooting / Activating the high limit safety
cut-out").
1.
f Either open the DHW valve of the tap or set the mono lever
f
mixer tap to "hot" until the water that flows out is free of air
bubbles.
f Check the safety assembly. When purging, ensure that a full
f
jet of water flows out.
f Insert the plug into the standard socket or set the fuse/MCB
f
in the fuse box.
f Select a temperature.
f

10.1.1 Appliance handover

f Explain the functions of the appliance to the user. Show the
f
user how to operate the appliance.
f Make the user aware of potential dangers, especially the risk
f
of scalding.
f Hand over these instructions and, if applicable, the instruc-
f
tions for any accessories.

10.2 Recommissioning

See chapter "Installation / Commissioning / Initial start-up".
16
| SH 10 SLi | SH 15 SLi

11. Settings

11.1 Setting the temperature limit

1 Limiting ring
2 Temperature selector
Placing the limiting ring behind the temperature selector allows
you to limit the setting range of the temperature selector to a
specific maximum temperature.
f Turn the temperature selector to zero (fully anti-clockwise
2.
f Pull off the temperature selector and the limiting ring.
f Push the limiting ring with the required maximum setting
f Fit the temperature selector in the zero setting (°C).

12. Shutdown

f Isolate the appliance from the power supply by removing the
f Drain the appliance (see chapter "Installation / Maintenance /

13. Troubleshooting

Fault
The appliance does
not supply hot water.
Loud boiling noises
inside the appliance.

13.1 Activating the high limit safety cut-out

f Push the reset button.
f
to "°C").
f
f
onto the adjusting shaft.
f
f
plug or by tripping the fuse/MCB in the fuse box.
f
Draining the appliance").
Cause
High limit safety cut-
out has responded.
The appliance is scaled
up.
f
2
1
Remedy
Remedy the cause of the fault.
If necessary, replace the tem-
perature controller. Restore the
function of the high limit safety
cut-out by pressing its reset
button.
Descale the appliance.