Page 30 of 32 of European Technical Assessment no. 23/0482, issued on 2023-09-05
Table C9.1: Displacements of the fixing system under tension load, temp. range 24°C/ 40°C
Fixing system
UNI-RT 12 (M12
threaded rod)
UNI-RT 16 (M16
threaded rod)
The displacement in the base material must be added
Table C9.2: Displacements of the fixing system under pressure load, temp. range 24°C/40°C
Fixing system
UNI-RT 12 (M12
threaded rod)
UNI-RT 16 (M16
threaded rod)
The displacement in the base material must be added
Table C9.3: Displacements of the fixing system under tension load, temp. range 50°C/ 80°C
Fixing system
UNI-RT 12 (M12
threaded rod)
UNI-RT 16 (M16
threaded rod)
The displacement in the base material must be added
Table C9.4: Displacements of the fixing system under pressure load, temp. range 50°C/ 80°C
Fixing system
UNI-RT 12 (M12
threaded rod)
UNI-RT 16 (M16
threaded rod)
The displacement in the base material must be added
RECA dimos anchor UNI-RT 12, RECA dimos anchor UNI-RT 16
Performances
Displacement under tension and pressure load
Tension load
Displacement
N
[kN]
5,14
4,57
Pressure load
Displacement
P
[kN]
5,14
5,14
Tension load
Displacement
N
[kN]
5,14
4,57
Pressure load
Displacement
P
[kN]
5,14
5,14
Displacement
NO
[mm]
[mm]
0,47
0,94
0,32
0,64
Displacement
PO
[mm]
[mm]
0,31
0,62
0,31
0,62
Displacement
NO
[mm]
[mm]
0,47
0,94
0,32
0,64
Displacement
PO
[mm]
[mm]
0,31
0,62
0,31
0,62
Annex C9
N∞
P∞
n∞
P∞