Page 17 of 32 of European Technical Assessment no. 23/0482, issued on 2023-09-05
dimos anchor UNI-RT 12, dimos anchor UNI-RT 16: Installation instruction (in concrete or
solid masonry)
RECA dimos anchor UNI-RT 12, RECA dimos anchor UNI-RT 16
Intended use
Installation instruction in solid base material
10. If the wall is uneven, the RECA dimos anchor UNI-RT
can be readjusted
The unevenness can, for example, be lined with polyamide
washers according to DIN 9021 with a diameter of 37x13x3
mm (Art.-No. 0421 012). The thermal separation module
may be unscrewed by a maximum of 3 mm using the
two-hole nut driver (Art. No. 0911 250 000). A resulting gap
should be sealed with a suitable sealant (e.g. S78).
A cover/sealing of the anchorage point is required when:
•
the deflection under shear stress is greater than
3 mm
•
the anchor is not perpendicular to the plaster
surface
•
the grain size or roughness of the plaster is
greater than 3 mm
•
the drill hole diameter in the plaster is larger
than 26 mm
With thick plaster or hard insulating material, the drill hole
must be drilled out to a depth (length of the thermal
break module) of 26 mm.
Annex B7