Page 11 of 32 of European Technical Assessment no. 23/0482, issued on 2023-09-05
Specification of intended use
Anchorages subject to:
•
Static and quasi-static actions in tension, pressure, shear or combined tension and shear or
combined pressure and shear load. The anchor shall not be used for the transmission of dead
loads of the thermal insulation composite system.
Base material:
Masonry and autoclaved aerated concrete – in accordance with ETA's
• ETA-13/0909 (VMU plus / VMU plus polar)
• ETA-17/0006 (VM-EA)
Cracked and uncracked concrete – in accordance with ETA's
• ETA-11/0415 (VMU plus / VMU plus polar)
Uncracked concrete – in accordance with ETA's for uncracked concrete
• ETA-16/0898 (VM-EA)
Temperature Range for use - if not restricted by injection mortar ETA:
Masonry
•
T
:
- 40°C to + 40°C (max. temperature: short-term +40°C and long-term +24°C)
a
•
T
:
- 40°C to + 80°C (max. temperature: short-term +80°C and long-term +50°C)
b
Concrete
•
T1:
- 40°C to + 40°C (max. temperature: short-term +40°C and long-term +24°C)
•
T2:
- 40°C to + 80°C (max. temperature: short-term +80°C and long-term +50°C)
Use conditions (Environmental conditions)
The use conditions for the base materials are given in the above-mentioned ETA's for the
respective substrates.
RECA dimos anchor UNI-RT 12, RECA dimos anchor UNI-RT 16
Product description
Specification of intended use
Annex B1