Page 15 of 32 of European Technical Assessment no. 23/0482, issued on 2023-09-05
dimos anchor UNI-RT 12, dimos anchor UNI-RT 16: Installation instruction (in concrete or solid
masonry)
Installation in concrete or solid brick:

RECA dimos anchor UNI-RT 12, RECA dimos anchor UNI-RT 16

Intended use
Installation instruction in solid base material
1. Drill a hole:
Observe the drilling method of the approval/assessment of
the injection mortar.
Concrete / solid brick: hammer drilling; aerated concrete:
Rotary drilling - without impact
dimos anchor UNI-RT 12: Drill hole diameter d
concrete: drill hole depth h
solid brick & aerated concrete: h
dimos anchor UNI-RT 16: Drill hole diameter d
concrete: drill hole depth h
solid brick & aerated concrete: h
(e = insulation thickness incl. plaster & t
2. Clean the drill hole:
The drill hole must be cleaned properly; see
approval/assessment of the injection system:
4x blow - 4x brush - 4x blow
3. Cut the dimos anchor UNI-RT to length:
The pre-assembled threaded rod M12 / M16 is already
completely screwed into the thermal separation module.
Correct length L
from the tip of the threaded rod to the
dK
lower edge of the cover plate of the thermal separation
module (see table):
UNI-RT 12
UNI-RT 16:
After determining the correct length, cut the threaded rod
M12 / M16 to length with a metal saw.
4. Note:
If the plaster is very thick and hard, use a Ø 26 mm drill bit
or „ream" the hole in the plaster to approx. 26 mm with the
drill.
= 14 mm,
0
≥ 80 mm + e,
1
≥ 110 mm + e
1
= 18 mm,
0
≥ 90 mm + e,
1
≥ 110 mm + e
1
)
tol