Herunterladen Diese Seite drucken

Lincoln SKF B Serie Gebrauchs- Und Wartungsanleitung Seite 7

Vorschau ausblenden Andere Handbücher für SKF B Serie:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 61
Installation and operation
Installation
Place unit in approximate location making
sure electric power connections are
accessible.
 Mark center locations of holes at bottom of
reservoir († fig. , page  or Fig. ,
page ).
– For models , MSO, 
1
and MSO drill six
/
7
holes. Use of
/
in (10 mm) bolts will
16
offer some flexibility in securing reser-
voir to equipment.
– For models  and MSO drill
5
four
/
in (15 mm) holes. Use of
8
(13 mm) bolts will offer some flexibility
in securing reservoir to equipment.
 Connect lubricant outlet of pump to sys-
tem with suitable hose capable of
  psi (241 bar) working pressure.
 Wire pump motor and vent valve as shown
(† fig. , page ).
NOTE
Verify red electric motor lead is con-
nected to positive side of circuit.
Motor will not run if wired incorrectly.
NOTE
Refer to pump model  and 
operation manual  for setting
pump control on  V
motor.
Operation
Fill reservoir
 Clean area around filling port.
 Remove lower () and upper () pipe
plugs from side of reservoir († fig. IPB ,
page ; or fig. IPB , page ).
 Attach appropriate bulk-filling pump to
lower inlet ( in NPT).
in (13 mm)
 Fill reservoir until grease appears at the
2
1
top 
/
NPT vent high level port.
4
 Remove bulk filling pump.
 Replace both pipe plugs.
1
/
in
2
WARNING

Do not overfill reservoir. Extreme pres-
sure can damage reservoir and/or pump
housing.
Failure to comply may result in death
or serious injury.
Fill reservoir
(MSO equipped)
Body and guide assembly (), pivot arm
(), supply line relief, follower () and
cover () work in combination with each
other to prevent grease from overfilling res-
ervoir during refill process († fig. IPB ,
page ; or fig. IPB , page ).
As grease fills reservoir, follower rises and
lifts pivot arm, forcing body and guide
assembly closed. When body and guide
assembly closes, pressure continues to rise
in supply line causing pump to stall. At that
point, supply line relief valve must be opened
to relieve pressure from system.
Operational procedure
 Verify relief valve is closed.
 Turn supply pump on.
 Supply pump stalls when gauge reaches
maximum.
 If grease level sensor or indicator option is
available with system, verify reservoir is
full of grease.
 Turn off supply pump.
 Open pressure relief valve to vent down
stall pressure. Make sure relief valve is
open long enough to remove pressure
from system.
 Disengage quick disconnect.
 Cap quick disconnect ends to prevent
contamination.
 Leave relief valve open until next fill cycle.

Werbung