7  Installation
DANGER
Risk of death due to electric shock
Contact with live parts results in a direct risk of
death due to electric shock.
n
In case of emergency or when fixing errors
or carrying out electrical work on the Wall-
box, comply with the following Safety
rules:
n
Disconnect.
n
Secure against being switched on
again.
n
Ensure that there is no voltage.
n
Earth and short-circuit.
Cover any adjacent live parts and
n
secure the danger area.
DANGER
Risk of death due to incorrect connection
If the electrical supply line is incorrectly connec-
ted, there is a direct risk of death due to electric
shock.
Observe the wiring diagram.
n
n
Assign the wire colours correctly.
1.
Divide the anti-kink protector into individual
parts. See figure 8.
2.
Fasten the cable entry grommet (2) with a
nut (M25) (3) in the Wallbox housing.
3.
Pull the anti-kink protector (1) over the char-
ging cable and push the charging cable
through the cable entry grommet from the
bottom to the top. The cable sheath must be
guided over the strain relief clamp as far as
it will go (1). See figure 9.
4.
Feed the charging cable through the anti-
kink protector and secure it on the cable
entry grommet.
5.
Detach the strain relief clamp from the com-
ponent bracket (1).
Choose the side according to the cable dia-
meter. See figure 11.
6.
Securely tighten the strain relief clamp with
the appropriate screws (4x17) using a screw-
driver (or cordless screwdriver) to a torque
of 1.65 Nm +8% (2). See figure 11.
7.
Connect the CP cable (colour white, dia-
meter 0.5 mm²) in the top right (single pole
terminal). See figure 10.
Note that the individual wires should be rou-
ted under the plastic bracket of the com-
ponent carrier.
8.
Insert and connect the 5 wires of the char-
ging cable in the connecting terminals as fol-
lows:
See figure 10.
1.
PE (green/yellow)
2.
Neutral (blue)
3.
L1 (brown)
4.
L2 (black)
5.
L3 (grey)
7.4 Connecting the infrastructure
cable
DANGER
Risk of death due to electric shock
Contact with live parts results in a direct risk of
death due to electric shock.
n
In case of emergency or when fixing errors
or carrying out electrical work on the Wall-
box, comply with the following Safety
rules:
n
Disconnect.
n
Secure against being switched on
again.
n
Ensure that there is no voltage.
n
Earth and short-circuit.
n
Cover any adjacent live parts and
secure the danger area.
DANGER
Risk of death due to incorrect connection
If the electrical supply line is incorrectly connec-
ted, there is a direct risk of death due to electric
shock.
n
Observe the wiring diagram.
n
Assign the wire colours correctly.
Note
n
When connecting the infrastructure cable,
observe the wiring diagram, see
and figure 13.
The Wallbox can be connected with 1 phase or 3
phases, see
Setting the power supply mains con-
figuration.
To use 1-/3-phase switching, the Wallbox must be
connected with 3 phases. To check whether
the Wallbox supports 1-/3-phase switching, see
Structure of the type name of the
1.
Strip the insulation from the wires to a
length of 12 mm.
2.
For 3-phase connection: Assign the colours
correctly and insert in the connecting ter-
minals from left to right in the following
sequence (see figure 12):
1.
PE (green/yellow)
2.
Neutral (blue)
figure 12
Wallbox.