6 Prerequisites
6.1 Assembly and installation location
Note
When selecting the assembly and installation loca-
tion, also observe the general safety instructions
for assembly and installation, see
mation.
Load-bearing capacity of the wall
The Wallbox is intended exclusively for stationary
use and therefore must always be mounted on a
wall. The wall must have a load-bearing capacity
of at least 40 kg.
Position
n
Mount the Wallbox at least 50 cm and a
maximum of 115 cm above the ground to
ensure accessibility.
n
Leave a minimum distance of 20 cm to the
Wallbox on all sides. See figure 1.
Electrical supply line
n
Observe the local energy provider's regu-
lations.
n
Make sure that a separate supply line is
available for installation of the Wallbox.
n
If necessary, install a separate supply line
that complies with the general standards for
cabling and building technology.
The electrical supply can be either flush-
mounted or surface-mounted as preferred.
The Wallbox requires an external residual
n
current circuit breaker (minimum RCD type
A). On the device itself, there is an inte-
grated DC residual current operated
37
protective device (6 mA) complying with IEC
62955.
n
The Wallbox is designed for connection and
operation on a mains voltage of 230 V (1-
phase) or 400 V (3-phase), 50/60 Hz.
n
Make sure that the rated voltage and current
of the Wallbox meet the standards for the
local power supply, so that the rated current
Safety infor-
of the supply line is not exceeded during
charging, see
n
All requirements for construction of low vol-
tage systems set out in VDE 0100 or the
local regulations are applicable.
n
A circuit breaker corresponding to the buil-
ding's wiring and the Wallbox device power
(see rating plate and
be fitted.
Further information
When selecting the installation location, also con-
sider the following:
The Wallbox is freely accessible for ope-
n
ration by authorised persons, see
mentation concept and target
n
Where possible, ensure that unauthorised
access is not possible.
n
Install the Wallbox where it can easily be
accessed by the vehicle.
n
Make sure that there is sufficient freedom of
movement for installation and for charging.
n
Ensure that a good network connection is
available:
LTE reception (optional)
o
WiFi connection in client mode
o
6.2 Ambient conditions
Technical
data.
Technical
data) must
6.3 Required tools
Drill/hammer drill
Docu-
group.
Torx screwdriver (TX20, TX25)
Slotted screwdriver 0.3 x 2 mm
Slotted screwdriver 1 x 4 mm
Pipe wrench
Socket size 13 mm
Stripping tool
Measuring tape/rule
Spirit level
Tweezers
n
Observe ambient specifications, see
nical
data.
n
To prevent damage caused by weather con-
ditions, install the Wallbox in such a way
that it is protected from direct exposure.
If necessary, provide sufficient cooling
n
and/or ventilation.
n
To utilise the full rated power, protect the
Wallbox from sunlight.
n
Some Wallbox versions are equipped with a
MID 2014/32/EU compliant energy meter,
and thus conform to the electromagnetic
ambient conditions for Class E1 equipment.
n
The Wallbox version conforms to
EMC 2014/30/EU with respect to elec-
tromagnetic ambient conditions.
Tool
6  Prerequisites
Tech-
Quantity
1
1
1
1
1
1
1
1
1
1