Herunterladen Diese Seite drucken

Ocmis Irrigazione RAIN CONTROL 4 Bedienungs- Und Wartungshinweise Seite 52

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 76
AUTOMATIC SWITCH OFF
When no data packets are provided to the tachometer for 45 minutes the "E TO" alarm switches off the sytem automatically.
Keep the "ON" key pressed to switch off the tachometer manually.
ADDITIONAL INFORMATION
Battery life – battery change
The tachometer is supplied with 2 AA 1.5 V batteries.
Their voltage can be checked at any time by pressing the key "BTTY"
If the battery voltage drops below 2.0V, the values displayed on the screen start flashing to give the low battery warning.
The system continues working up to a charge value of 1.8V and then it switches off to prevent damage to the electronic compo-
nents.
To change the batteries unscrew the rear cover using an appropriate tool.
ATTENTION : change the battery in a clean , dry room. When the cover is removed make sure that the card is not in contact
with liquids or powders which might damage it.
Batteries must be removed at the end of the season.
The device WI-FI has an average duration of 60 hours of continued operation
OPTIONS
The tachometer can be provided with a magnetic base to be installed on the roof of the tractor cabin to allow the use of the de-
vice even in the tall corn
The operations to perform are the following :
unscrew the tachometer antenna
connect the antenna to the magnetic base
connect the magnetic base cable to the tachometer
place the magnetic base on the steel roof of the tractor cabin