8. SPECIFICATION
Skylla-i
Input voltage (VAC)
Input voltage range (VAC)
Input voltage range (VDC)
Maximum AC input current @ 180 VAC
Frequency (Hz)
Power factor
Charge voltage 'absorption' (VDC)
Charge voltage 'float' (VDC)
Charge voltage 'storage' (VDC)
Charge current (A)
(2)
Charge current starter batt. (A)
Charge algorithm
Battery capacity (Ah)
Charge curve, Li-Ion
Temperature sensor
Can be used as power supply
Remote on-off port
VE.Can communication port
Synchronised parallel operation
Remote alarm relay
Forced cooling
Protection
Operating temp. range
Humidity (non-condensing)
Material & Colour
Battery-connection
230 VAC-connection
Protection category
Weight kg (lbs)
Dimensions hxwxd in mm
(hxwxd in inches)
Safety
Emission
Immunity
1) Output voltage range 20-36 V.
Can be set with rotary switch or
potentiometers.
24/80 (1+1)
16 A
(1)
80 A
4 A
400-800 Ah
4 stage, with on-off control or CAN-bus control
Two RJ45 connectors, NMEA 2000 protocol, galvanically isolated.
Integrated 12 V CAN-bus power supply, 30 VDC maximum
DPST
AC rating: 240 VAC/4 A
Battery reverse polarity (fuse)
ENCLOSURE
STANDARDS
EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
2) Up to 40 °C (100 °F) ambient.
Output will reduce to 80 % at 50 °C, and to 60 % at 60 °C.
3) When connecting the Skylla-i in a VE.Can network that also contains devices connected to a
48 V battery bank, make sure to use a special RJ-45 cable, which has pins 2 and 6 (NET-S / V+)
not connected.
15
24/80 (3)
24/100 (1+1)
230 V
185-265 V
180-350 V
45-65 Hz
0,98
28,8 V
27,6 V
26,4 V
3 x 80 A
100 A
(max total output: 80 A)
n. a.
4 A
7 stage adaptive
Yes
Yes
Yes (can be connected to a Li-Ion BMS)
Yes, with the CAN-bus
DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC
Yes
Output short circuit
-20 to 60 °C (Full output current up to 40 °C)
max 95 %
aluminium (blue RAL 5012)
M8 bolts
screw-clamp 10 mm² (AWG 7)
IP 21
7 (16)
405 x 250 x 150
(16.0 x 9.9 x 5.9)
EN 60335-1, EN 60335-2-29
EN 55014-1, EN 61000-6-3, EN 61000-3-2
24/100 (3)
20 A
3 x 100 A
(max total output: 100 A)
n. a.
500-1000 Ah
(3)
Over temperature