system panel enabled set {OFF=0|ON=1}
system panel enabled show
system panel port all set {OFF=0|ON=1}
system panel port all show
timer
timer enabled set {OFF=0|ON=1}
timer enabled show
timer syslog facility set {0..23}
timer syslog facility show
timer syslog verbose set {0..7}
timer syslog verbose show
timer {rule_num} enabled set {OFF=0|ON=1}
timer {rule_num} enabled show
timer {rule_num} name set "{name}"
timer {rule_num} name show
timer {rule_num} {FROM=0|UNTIL=1} set "{yyyy-
mm-dd}"
timer {rule_num} {FROM=0|UNTIL=1} show
timer {rule_num} trigger jitter set {0..65535}
timer {rule_num} trigger jitter show
timer {rule_num} trigger random set {0..100}
timer {rule_num} trigger random show
timer {rule_num} trigger {HOUR=0|MIN=1|SEC=2|
DAY=3|MON=4|DOW=5} set "{time_date_list}"
timer {rule_num} trigger {HOUR=0|MIN=1|SEC=2|
DAY=3|MON=4|DOW=5} show
timer {rule_num} action mode set {SWITCH=1|
CLI=2}
timer {rule_num} action mode show
timer {rule_num} action {SWITCH1=0|SWITCH2=1}
{OFF=0|ON=1} set "{port_list}"
timer {rule_num} action {SWITCH1=0|SWITCH2=1}
{OFF=0|ON=1} show
timer {rule_num} action delay set {0..65535}
timer {rule_num} action delay show
timer {rule_num} action console set "{cmd}"
timer {rule_num} action console show
timer {rule_num} action hash set "{data}"
timer {rule_num} action hash show
timer {rule_num} delete
timer delete all
vt100
vt100 echo set {OFF=0|ON=1}
vt100 echo show
vt100 numeric set {OFF=0|ON=1}
vt100 numeric show
vt100 reset
Hinweise
1. Legacy - Der Befehl ist von einer neueren Version abgelöst worden
2. Befehl kann auf allen Ebenen ausgeführt werden
3. Die Ausgabe kann 2 Zeilen umfassen - die erste Zeile zeigt den aktuellen Zustand,
die zweite Zeile den Status nach einem Neustart
4. Die Ausgabe kann mehrere Zeilen umfassen
5. Bitte die Energie Sensor Tabelle konsultieren, um den richtigen Index zu finden
6. Bitte die Tabellen Externer Sensor Feld und Externer Sensor Typ konsultieren,
um den richtigen Index zu finden
Expert Power Control 8101
blocks panel buttons w hen not enabled
show s if panel buttons are enabled
enable siw tch all relays from panel buttons
show s if siw tch all relays from panel buttons
enabled
enters cmd group "timer"
enables timer functions
show s if timer a enabled
sets facility level for timer syslog
show s facility level for timer syslog
sets verbose level for timer syslog
show s verbose level for timer syslog
enables rule
show s if rule is enabled
sets name of rule
show s name of rule
sets date range of rule
show s date range of rule
sets jitter for rule
show jitter of rule
sets probability for rule
show s rule probability
sets time date list
show s time date list
sets sw itch or cli cmd
show s if sw itch or cli cmd
sets port list for sw itch cmd
show s port list for sw itch cmd
delay betw een cmds
show s delay betw een cmds
sets cmd string
show s cmd string
sets action binary form
show s action binary form
delete one timer
delete all timer
enters cmd group "vt100"
sets console echo state
show s console echo state
sets numeric mode
show s numeric mode state
resets terminal