Fig. 19: Positioning the forked spacer
9.2.3 Changing the motor
52
• Slightly loosen the coupling screws. Slightly open the pre-assembled
coupling.
• Install the motor with suitable hoisting gear and screw the lantern/
motor (and adapter ring for few BL pumps) connection together.
• Slide the forked spacer (Fig. 19, item 10) between the lantern and
coupling. The forked spacer must sit there without any play.
• First, slightly tighten the coupling screws (Fig. 1/2/3/4/5, item 1.41)
until the coupling half-shells are in contact with the shims.
• Afterwards, screw the coupling together evenly. In doing so,
the specified distance between the lantern and the coupling of 5 mm
is automatically adjusted via the forked spacer.
• Remove the forked spacer.
• Install the coupling guard.
• Connect the motor or mains connection cables.
Pump type design C:
• Pull a new mechanical seal onto the shaft. A commercially available
dishwashing liquid can be used as a lubricant (if required, insert the
key and the shim again).
• Install the impeller with washer(s) and nut, countering at the impel-
ler's outer diameter while doing so. Avoid damage to the mechanical
seal due to jamming.
• Slowly insert the pre-assembled drive with lantern unit (coupling,
shaft mechanical seal, impeller) into the pump housing using suitable
hoisting gear and screw it into place.
• Connect the motor or mains connection cables.
The motor bearings are maintenance-free. Increased bearing noises
and unusual vibrations indicate bearing wear. The bearing or motor
must then be changed. The drive may only be replaced by the Wilo
customer service.
• Switch off the system (voltage-free state) and secure it against being
switched on again.
• Make sure it is not live.
• Earth the work area and short-circuit.
• Close the shut-off devices upstream and downstream of the pump.
• Depressurise the pump by opening the air vent valve
(Fig. 1/2/3/4/5/6, item 1.31).
Dismantling:
DANGER! Risk of scalding!
Due to high fluid temperatures there is a danger of scalding.
• If the fluid is hot, allow it to cool down before all work.
NOTICE:
• When tightening screw connections in conjunction with the work
described in the following: Observe the screw tightening torque for
the thread type (see list "Tab. 5: Screw tightening torques" on
page 54).
• Disconnect the motor connection cables.
• Dismantle the coupling guard (Fig. 1/2/3/4/5/6, item 1.32).
Pump type design A/B:
• Dismantle the coupling (Fig. 1/2/3/4/5, item 1.5).
• Loosen the motor fastening screws (Fig. 1/2/3/4/5, item 5) on the
motor flange and lift the motor off the pump with suitable hoisting
gear. On BL pumps, the adapter ring comes loose (Fig. 3, item 8).