will be made from the outside using the
supplied M6 screws.
b) To the internal laterals of the furniture
through floating hole
wich exist in each side of the body hood.
This fixation will be made from the inside
part
of
the
disassembling the filters.
The lower part of the extractor must be
located at a minimum height of 50 cm above
the hob for electric cookers and 65 cm for gas
Before seeking technical assistance carry out the following checks first:
Defect
The extractor does not
work
The extractor does not
blow
enough
or
vibrates
The lamps do not light
Height above gas hob: 75 mm minimum.
NEVER PLACE THE COOKER HOOD OVER
AN EYE-LEVEL GRILL.
This appliance is not intended for use by
young children or infirm persons without
supervision.
We
recommend
connected by a qualified electrician, who is a
member of the N.I.C.E.I.C. and who will
comply with the I.E.E. and local regulations.
Should the colour of the wires in the mains
lead for the appliance not correspond with the
cooker
hood,
Possible cause
The cable is not connected
No current is reaching the
plug
Filter saturated with grease
Outlet obstructed
Inadequate air conduit
Lamp broken
that
the
appliance
cookers. If the instructions of a gas cooker
indicate a greater distance these must be
observed.
To achieve optimum performance the length of
the outlet hose should not exceed 4 meters or
include more than two 90º angles (elbows).
Although
after
recommended, activated carbon filters may be
used, which allow the gas to be returned to
the kitchen through the outlet pipe.
Connect the mains cable
Revise/repair the electricity circuit
Clean or substitute the filter
Eliminate obstructions
Contact the installer and follow instructions of this
manual
Contact the Customer Service
ILCOS D Code: DSL-12-S-450
This appliance must be connected by a
competent person, using fixed wiring via a
DOUBLE POLE SWITCHED FUSED SPUR
OUTLET.
Young children should be supervised to
ensure that they do not play with the
appliance.
is
coloured markings identifying the terminal in
your spur box proceed as follows:
The wire which is coloured blur must be
connected to the marked N (Neutral) or
coloured Black.
venting
to
the
Solution
EN
outside
is
23