- If there is a risk of flooding, fit the plug connec-
tions in the flood-proof area.
• Ensure that the mains voltage corresponds to the
specifications on the type plate.
• Carry out the electrical installation in accordance
with the national regulations.
• Only connect the product to a socket with a residual
current circuit breaker (FI switch) with a rated resid-
ual triggering current of up to 30 mA; Fuse at least
6 amps.
• Before each use, always check the product, cable
and plug for damages. Defective cables must not be
repaired but replaced with a new ones. Have prod-
uct damages repaired by a specialist.
• If the connection cable of this product is damaged it
must be replaced by the manufacturer or their cus-
tomer services personnel or by a similarly qualified
person, in order to avoid hazards.
• Do not use the cable to pull the plug out of the out-
let.
• Protect the cable from heat, oil and sharp edges.
• Do not carry or attach the product by the cable.
• Use only extension cables that are splash-proof and
intended for outdoor use. Always unroll a cable drum
completely before use. Check the cable for damage.
• Pull out the mains plug before all work on the prod-
uct, in work breaks and when not in use.
• Mains connection cables shall not have a smaller
cross-section than rubber hose lines with the desig-
nation H07 RN-F. The cable length must be 10 m.
The conductor core cross-section of the extension
cable must be at least 1.5 mm
Lubricants are used inside the pump and can contami-
nate the drained fluids, if the product is improperly op-
erated or damaged.
m WARNING! This power tool generates an electro-
magnetic field during operation. This field can impair
active or passive medical implants under certain cir-
cumstances. In order to prevent the risk of serious
or deadly injuries, we recommend that persons with
medical implants consult with their physician and the
manufacturer of the medical implant prior to operating
the power tool.
6. Residual risks
The product has been built according to state-of-the-
art and the recognised technical safety rules. However,
individual residual risks can arise during operation.
.
2
www.scheppach.com
• Health hazard due to electrical power, with the use
of improper electrical connection cables.
• Furthermore, despite all precautions having been met,
some non-obvious residual risks may still remain.
• Residual risks can be minimised if the "Safety In-
structions" and the "Intended Use" together with the
operating manual as a whole are observed.
• Avoid accidental starting of the product: the operating
button may not be pressed when inserting the plug in
a socket. Use the tool attachment that is recommend-
ed in this operating manual. This is how to ensure that
your product provides optimum performance.
• Keep your hands away from the working area when
the product is in operation.
7.
Technical data
Product L x W x H
Mains power
connection
Rated input
Max. delivery flow
Max. delivery height
Max. delivery pressure
Max. suction height
Pressure and suction
connection
Max. water temperature
Protection class
Protection category
Operating mode*
Weight
Subject to technical changes!
Noise
m Warning: Noise can have serious effects on your
health. If the machine noise exceeds 85 dB, please
wear suitable hearing protection.
Information about noise level measured in accord-
ance with EN ISO 3744:2010
Noise data
Sound power level L
WA
Sound pressure level L
pA
Uncertainty K
wa/pA
450 x 230 x 280 mm
230 V~ / 50 Hz
1300 W
6000 l/h
48 m
4.8 bar
8 m
G1"
35° C
I
IPX4
S1
9.85 kg
85 dB
70.84 dB
1.64 dB