Operation
ATTENTION
Flat pleated filter missing
Device damage
Always work with the flat pleated filter inserted.
Note
Pay attention to the latest part numbers when purchas-
ing and installing filter bags and flat pleated filters.
Information on accessories and spare parts can be
found at www.kaercher.com.
Dry vacuuming
ATTENTION
Vacuuming cold ashes
Device damage
Only vacuum cold ash with an ash pre-separator.
ATTENTION
Defective or wet flat pleated filter
Device damage
Before initial startup, check the flat pleated filter for
damage and replace it if necessary.
Only vacuum with a dry flat pleated filter.
Note
Replace the filter bag in good time, as a filter bag that is
too full could be damaged. The fill degree of the filter
bag depends on the amount of dirt vacuumed. The filter
bag should be replaced more frequently when vacuum-
ing fine dust, sand, etc.
Wet vacuuming
ATTENTION
Wet vacuuming with a filter bag
Device damage
Do not use a filter bag when vacuuming wet.
ATTENTION
Operation with full container
When the container is full, a float switch closes the suc-
tion opening and the device runs at a higher speed.
Switch off the device immediately and empty the con-
tainer.
Note
If the device falls over, the float can also close. To make
the device capable of vacuuming again, set up the de-
vice, switch it off, wait 5 seconds and then switch it on
again.
Working with power tools (only for devices
with a built-in socket)
CAUTION
Unintentional starting of the power tool
Injury or property damage
Make sure that the power tool is ready for operation as
soon as it is connected to the device socket.
1. Connect the suction hose.
Illustration G
2. If necessary, adjust the adapter to the connection di-
ameter of the power tool using a suitable tool.
3. Put the adapter on the handle of the suction hose.
4. Mount the suction hose with the adapter on the pow-
er tool.
Illustration M
5. Plug the mains plug of the power tool into the device
socket.
Illustration N
6. Set the trigger to
Illustration L
.
The suction is activated automatically.
Note
Note the maximum connected load (see information on
the device socket).
Note
As soon as the power tool is switched on, the suction
turbine starts up with a 0.5 second delay. If the power
tool is switched off, the suction turbine continues to run
for approx. 5 seconds in order to suck in the residual dirt
in the suction hose.
The blower function can be used to clean areas that are
difficult to reach or where vacuuming is not possible,
e.g. leaves in a gravel bed.
 Insert the suction hose into the blower connection.
The blower function is now activated.
Illustration O
Interrupting operation
1. Set the trigger to "0 OFF".
The device is switched off.
2. Variant 1: Place the handle of the suction hose in the
intermediate parking position.
Illustration P
Variant 2: Attach the floor nozzle in the parking po-
sition.
Illustration Q
1. Set the trigger to "0 OFF".
The device is switched off.
2. Pull out the mains plug.
3. Remove the device head.
Illustration B
4. Empty the container.
Illustration R
5. Storage possibility:
Illustration Y
Note
The suction hose can be wrapped around the device
head and attached to the device head with the help of
the hose collar.
6. Store the device in a dry and frost-proof room.
Care and service
General care instructions
 Clean the device and plastic accessory parts with a
commonly available plastic cleaner.
 Rinse the container and accessories with water, as
necessary, and dry them before further use.
Clean the filter box / flat pleated filter
1. Unlock the filter box and fold it out.
Illustration S
2. Remove the filter box.
Illustration T
3. Empty the filter box into a waste container. In the
case of heavy soiling, tap the filter box against the
edge of the waste container. The flat pleated filter
does not have to be removed from the filter box.
Illustration U
If necessary, clean the flat pleated filter separately.
4. To do this, remove the flat pleated filter from the filter
box.
Illustration V
English
Blower function
Ending operation
9