Safety equipment
CK 20 S, CKZ 20 S and CKR 20 S are
equipped with over temperature protec-
tion, which switches off the heating ele-
ment and the fan in the event of a malfunc-
tion. If the over temperature protection
operates, the cause of this must be found
out and corrected (eg covered air-exit
opening). The heater will operate again
after a cooling time of several minutes. If
the over temperature protection repeat-
edly operates when the unit is switched on
further advice should be sought from
Stiebel Eltron.
What to do in case . . .
Using the original Stiebel Eltron sparepart
(Order-Nr. 02 06 71).
When the fan heater does not heat up,
firstcheck the fuse. If the fuse is in order,
than call the installer.
If the electric cable needs to changed,
than it must be done by a scilled installer.
Handing over
Hand over the operating and
installation instructions to the
user. Explain the functions of the unit
and ensure that the user pays particular
attention to the safety instructions
especially the fact that the air inlet and
outlet must never be covered.
Technical data
Power consumption
Voltage
Height
Width
Depth
Weight approximately
Temperature adjustment
Frost protection
Class of protection
Splash proofing
Licences/certificates
Fig. 13
2 kW
230 V
460 mm
335 mm
123 mm
4,4 kg
approx. +5 °C to approx. +30 °C
approx. +5 °C
, IP 13 B
see the rating label
PBTP/ASA Polybutylenterephtalat/
Acrylnitril-Styrol-Acrylester
PA
Polyamid
PC
Polycarbonat
PE
Polyethylen
PS
Polystyrol
Si
Silicon