Operating instructions
Always observe the operating instructions and "Im-
portant operating notes" prior to starting! The vehicle
owner is responsible for correct operation of the appliance.
Control panel with thermostat
c
230 V ~
a = Rotary switch "Off"
b = Rotary switch "On" power settings:
500 – 1000 – 2000 W
c = Rotary control knob for room temperature
(illuminated by green indicator lamp "operation")
Switching on
Before switching on, ensure that the fuse protection for
the power supply of the camp site is sufficient for the
selected power setting (b – see "Technical Data").
Important
The electric feed line for the caravan must be fully unwound
from the cable drum.
To switch on, turn the rotary switch to the desired output
level (b).
Set rotary control knob (c) to the desired room temperature.
The thermostat setting on the control panel (1 – 9) must be
determined individually depending on the heating requirement
and the type of vehicle.
For an average room temperature of about 23° C, we
recommend a thermostat setting of about 6 – 8.
Switching off
Switch the heating system off at the rotary switch (a).
6
Ultraheat
b
2000
a
b
500
b
1000
Technical Data
Power supply
230 V ~, 50 Hz
Power consumption at power setting
500 W: 2.2 A
1000 W: 4.5 A
2000 W: 8.5 A
Weight
approx. 2 kg
Declaration of conformity
The Truma Ultraheat has been tested by the DVGW as an
auxiliary electric heater and complies with gas equipment
directive 90/396/EEC, EMC directive 89/336/EEC, low voltage
directive 72/23/EEC, heating equipment directive 2001/56/EC
and the associated EC directives and is entitled to bear the CE
symbol.
The CE Product Identity Number of the heating system
remains valid without change.
Accessories
Extension cable for the control panel, length 5 m
(part no. 34300-01) – not illustrated –
Remote sensor FFC 2, monitors the room temperature,
regardless to the position of the control panel, comes with a
4 m connecting cable (part no. 34201-01).