Fig. 12
Grip part
Griff
Fig. 13
3.5.
Checking of refrigerant leakage at coupling connecting part
After the connection of coupling, check the leakage using the
-efrigerant leak-detector.
3.6.
Insulation of low side coupling
_
After checking the refrigerant leakage, cover the low side coupl-
ing with the insulation pipe attached to the unit and stick it to
the coupling after stripping the paper out of its surface as shown
in Fig. 14.
Be careful of the gap between the insulation pipe and the
coupling plate, the insulation pipe and insulation pipe-B. Make
sure to be no- gap.
No gap
Dicht
Fig. 14
3.7,
Wiring (RAS-2252GF - RAC-2259G)
For wiring of RAS-2142CF + RAC-2142C refer to another instal-
cation.
;
(1) Remove the suction grille pulling the knobs of suction grille.
Right turning direction
Vorgeschriebene Drehrichtung
Exclusive use torque wrench
Spezial Drehmomentschliissel
Abb. 12
Piping connection line
' Verbindungslinie der Leitung
Abb. 13
3.5.
Priifung auf Leckage an den Verbindungsstellen.
Nach Herstellung der Verbindungen sind die Kupplungen auf
eventuelle Kaltemittel-Leckagen zu iiberpriifen, bei Verwendung
eines Leckstellensuchers.
3.6.
Isolierung des unteren Teiles der Kupplung.
Nach Priifung auf Leckage ist der untere Teil der Kupplung mit
dem mitgelieferten Isoliermantel zu umwickeln. Die Folie auf der
Innenseite des Mantels wird abgezogen und gema Abb. 14 ange-
bracht.
Das andere Teil der Kaltemittel-Leitungen ist dann mit dem
mitgelieferten. Isoliermantel-B zu isolieren (siehe Abb. 14) und
'mit dem mitgelieferten Vinylklebeband zu befestigen. Wenn der
Isoliermantel-B zu lang ist, wird er so gekiirzt, da er das Kupfer-
rohr zwischen Wand und Kupplung vollstandig isoliert.
Coupling plate
a
Kupplung platte
Low side coupling
Untere Seite der Kupplung
Insulation pipe
Isoliermantel
Insulation pipe-B
{soliemantel-B
Abb. 14
3.7..
Verkabelung (RAS-2252GF - RAC-2259G)
Die elektrische Verdrahtung
der modell, RAS-2142CF-
RAC-
2142C ist in einer anderen Montage anleitung beschrieben.
(1) Das Ansauggitter abnehmen, indem die Knopfe des Ansaug-
gitters abgezogen werden.
Lift up only a little and
remove pulling forward.
{> Etwas auheben und nach
Terminal board
Klemmleiste
een es
yy)
N
Terminal board
Klemmieiste
Line cord
Anschlufikabel
Connecting cords
Elektrisches Verbindungskabel
Cooling unit
Kithleinheit
(Zimmergerat)
Fig. 18
4, Checking procedure after installation
4.1.
Confirm the smooth water flowing from the drain hose by
pouring some water into the evaporator pan.
;
4.2.
Arrange the penetrating part of the wall presentably with
the bush for refrigerating pipes and sealer attached to the pipe
set, as shown in Fig. 21.
Wall
Mauerwerk
Sealer
Fiillmasse
!
|
Indoor side
Innenseite
Fig, 21
4:3,
After setting the thermostat dial to "COOLER"
or "*«
(TEST)" start the running of unit and check the starting voltage
at the consent and confirm the checked voltage value is above
90% of rated voltage.
5. Turning the direction of Top grille
FRONT
NISCHARCE
TOD
NICCHARME
Refrigerating pipes
K4ltemittelleitungen
(Br
Sealer
Connecting cords
x
}
Fiillmasse
Elektrisches Verbindungskabel CF
' Schutzrohr
Abwasserschlauch
Van
sharan
Anciofi
anf
Terminal board
Klemmleiste
Band
Elektrischse
Kondensatoreinheit
Verbindungskabel
(Aufengerat)
(RAC-2259G)
Fig. 19
Abb. 19
Condensing unity
(Aufengerat)
Electric board
Elemmleiste
Connecting cords.
:
Elektrisches Verbindungskabel
Electric cover
Condensing unit
4. Priifung nach Montage
4.1.
Der ungehinderte Abflu& des Wassers durch den Abwasser-
schlauch wird gepriift, indem etwas Wasser in die Verdampfer-
pfanne gegossen wird.
4.2..
Der Mauerdurchbruch ist mit dem mitgelieferten Material,
Mauerdurchfihrung fiir Kaltemittelleitungen und Fiillmasse, zu
verputzen. Vgl. Abb. 21.
Bush for refrigerating pipes
Mauerdurchfthrung fiir Kaltemittelleitungen
=
Wrapping with vinyl tape
Umwicklung mit Vinyiband
Bush for refrigerating pipes
Maverdurchttihrung fur
Kaltemittelleitungen
Abb. 21
5. Anderung der Einbaurichtung des oberen Gitters