INSTALLATION
Installation
Undo the screws on the air duct assembly, pull them out
and remove the air damper(s). Protect from damage.
2
4
3
1 Swinging panel
2
Booster
heater
element
E8
3 Locking clips
4 Temperature controller N2
Secure temperature controller N2 (113ac, with purple
dot) to the back of the air duct assembly with two M3x6
self-tapping screws.
Note
The metal cap of the temperature controller must lie
flat.
Install
booster
heater
element
Engage the locking clips (two on heating element)
into the long slits on the right-hand side of the air duct
assembly.
Engage the remaining clip(s) into the underside of the air
duct assembly.
Slide the swinging panel onto the heating element.
Fix the heating element on the locking clips.
Position the swinging panel into the long slits on the left-
hand side of the air duct assembly. Interlock the swinging
panel to the underside.
E8.
7.2
Electrical
connection
Material
losses
Take care to ensure that the wires do not touch any
live parts or the interior wall.
Note
1
Observe the wiring diagram (see chapter "Specifica-
tion / Booster
heater
Wire up the heating element and temperature controller N2
using the wiring harness supplied.
Plug the end of the wiring harness into the temperature
controller using two blade terminal sleeves.
Plug the remaining two blade terminal sleeves (located
centrally) into the heating element connections.
Fix the wiring harness into the clip(s) on the underside of
the air duct assembly.
Slide the free end of the wiring harness through the front
opening in the lower part of the interior wall (in the con-
trol panel interior).
Plug the air damper(s) back into the air duct assembly.
Slide the air duct assembly into the appliance (allowing
the wiring harness with silicone hose to gently follow into
the control panel interior, without wedging it) and secure
the assembly with screws.
Connect up the free end of the wiring harness according to
the following table.
Designation
Wire
s
Wire (blade terminal)
The wires should be positioned as follows:
Run both wires from bottom to top behind terminal X2.
Fix the wires into the cable retainers provided.
Connect up the relay assembly according to the following
table.
Designation
3-coreconnecting cable
Black wire (blade terminal —blade terminal)
Black wire (blade terminal —end sleeve)
Blue wire (end sleeve —end sleeve)
The wires should be positioned as follows:
Passthe black wires from below through the cable grom-
met in the angled panel. Fix the wires into the cable ties
and cable retainers provided.
Pass the
blue
wire
behind
nal X2. Fix the wire into the cable retainers provided.
connection").
installation
From
To
Wiring har-
connect
ness
bottom
Wiring har
ness
installation
From
To
A3
X17 (A1)
LH (X4)
connect
bottom
connect
at
top
terminal
X4 down
to termi-
z
at
at
9