2. 3. DESCRIPTION AND CONNECTIONS
Switch 1
ON
Drive with coder sensor
OFF
Drive without coder sensor
Switch 2
(not used)
ON
Not used
OFF
Not used
Switch 3
ON
5 A max. per output
OFF
3 A max. per output
Switch 4
ON
Activates the temperature sensor
OFF
Deactivates the temperature sensor
Switch 5
ON
Closing in the event of wind
OFF
Opening in the event of wind
A
A
12 Vdc or 24 Vdc power supply -> Safety
isolating transformer (SELV) – 3 A / 5 A:
B
B
+
Maximum current allowed on switch 3
Drive output
C
C
12 or 24 Vdc drive - 3 A/5 A: Maximum
current allowed on switch 3
D
D
+
Lighting output
E
E
PWM 24 Vdc - 4 A
F
F
+
Drive coder input
G
G
Coder input (ILS or HALL) drive 1
H
H
Coder 2 input (ILS or HALL) drive 1
I
I
-
Power supply output: 24 Vdc/- 300 mA max.
J
J
+
Rain sensor
O
O
Contact
Dry contact input
P
P
Common
Q
Q
-
Power supply output: 24 Vdc/- 300 mA max.
R
R
+
External antenna
T
T
Signal Conductor
S
S
GND Shielding braid
20
External
External
antenna
antenna
Power supply
Power supply
output
output
Rain sensor
Rain sensor
(switch 1 = ON)
©
Copyright
S S T T
R R
Q Q
O O P P
A A
C C
D D
C C
D
D
G G H H I I J J
2019 - 2020 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
CONTROL UNIT P.TILT RTS M+L
PROG button.
PROG button.
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
B
B
Power supply
Power supply
E E
F F
Lighting output
Lighting output
Drive output
Drive output
Drive output S1
Drive output S1
Switch 1
Switch 1
Switch 2
Switch 2
Switch 3
Switch 3
Switch 4
Switch 4
Switch 5
Switch 5
input
input
HALL PNP
HALL PNP