LED indication
PIR
Red LED
Alarm relay
Start up
Closed
Low voltage
Open (Alarm)
PIR intruder
Open (Alarm)
alarm
PIR/AM
Red
Yellow
LED
LED
Start up
Low voltage
PIR intruder
alarm
Latched PIR
(Memory)
AM alarm
After AM reset
Technical fault
Continuously on
Normal blinking (1 Hz)
Fast blinking (4 Hz)
* Depends on the setting of the DIP switch SW4.
Specifications
Detector
Signal processing
Range
Optical
Memory
Input power
Peak-to-peak ripple
Detector start-up time
Normal current
Current in Alarm
Maximum current
(LED on)
Mounting height
Target speed range
Alarm (NC) / Tamper relay
characteristic
Pry-off tamper
AM relay characteristic
PIR alarm time
Operating temperature
125 × 55 × 60 mm
Dimensions (H x W x D)
Relative humidity
Weight
IP/IK rating
P/N 146576999-1 (ML) • REV D • ISS 08MAR19
All manuals and user guides at all-guides.com
To reset
Automatically after 25 s
Apply correct voltage
Automatically after 3 s
Alarm
AM
To reset
relay
relay
Closed
Closed
Automatically
after 60 s
Open
Open
Apply correct
(Alarm)
(Alarm)
voltage
Open
Automatically
(Alarm)
after 3 s
Switch to Night
mode
Open*
Open
See DIP
(Alarm)
(Alarm)
switch 3
Switch to
Night mode
Open
Do a successful
(Alarm)
walk test
EV1116-D
EV1116AM-D
PIR
PIR + AM
DSP
16 m
11 high-density mirror curtains
Yes
9 to 15 VDC (12 V nominal)
2 V (at 12 VDC)
25 s
60 s
4.4 mA
10 mA
1.2 mA
3.8 mA
11 mA
24 mA
1.8 m to 3.0 m
20 cm/s to 3 m/s
10 cm/s to 4 m/s
80 mA
80 mA
30 VDC, resistive
30 VDC
Optional
On-board (Yes)
80 mA at 30 VDC
max.
3 s
−10 to +55°C
125 × 65 × 60 mm
95% max.
150 g
IP30 IK02
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
AUTHORIZED EU REPRESENTATIVE:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR SALE
and disclaimers
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY "AUTHORIZED
DEALER" OR "AUTHORIZED RESELLER", IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/
or scan the QR code.
Certification
European Union
UTC Fire & Security hereby declares that this
directives
device is in compliance with the applicable
requirements and provisions of the Directive
2014/30/EU and/or 2014/35/EU. For more
information see www.utcfireandsecurity.com or
www.interlogix.com.
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.utcfssecurityproducts.eu/recycle/
Contact information
www.utcfireandsecurity.com or www.interlogix.com
For customer support, see www.interlogix.com/customer-
support.
DE: Installationsdatenblatt
Einführung
Die EV1100-D-Serie umfasst die Bewegungsmelder EV1116-D
und EV1116AM-D PIR. Die Melder verfügen über einen
patentierten Spiegel sowie Pyro- und
Signalverarbeitungstechnologie.
Installationsanleitung
Die Technologie in diesen Meldern dient zur Vermeidung
falscher Alarmmeldungen. Dennoch sollten Sie potenzielle
Instabilitätsfaktoren vermeiden (siehe Abb. 1), darunter:
Direkte Sonneneinstrahlung auf den Melder
Starke Zugluft am Melder
Hitzequellen innerhalb des Erfassungsbereichs des
Melders
Tiere innerhalb des Erfassungsbereichs des Melders
5 / 10